6 1 8 3 BASF MAGNETICS NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 153| | | Capacity form/unform 8/ 10 MB Heads 6| | | Seek time / track 61.0/ 1.2 ms Sector/track 9| | | Controller MFM / ST506 Precompensation 64 Cache/Buffer KB Landing Zone 173 Data transfer rate 0.625 MB/S int Bytes/Sector 1024 0.625 MB/S ext Recording method MFM operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 4 50 | -40 70 Power: sleep W Humidity % 15 80 | 5 95 standby W Altitude km -0.300 3.000| -0.300 14.000 idle W Shock g 3 | 10 seek 33.0 W Rotation RPM 3600 read/write W Acoustic dBA spin-up W ECC Bit MTBF h 11000 Warranty Month Lift/Lock/Park NO Certificates UL1950 ********************************************************************** L A Y O U T ********************************************************************** BASF 6180 FIXED DISK DRIVE SPECIFICATION 80307-054, 11/82 +---------------------------------------------------------+ | 20XX | |XX | |XX J2 B | |XX | |+-+ | || |J5 | |+-+ | 34XX | |XX | |XX | |XX J1 A | |XX | Terminator |XX | +------+(2F) |XX | +------+ | | Option +------+(2G) JJ2XX J3 P | Switches------+JJ1 x |XX +---------------------------------------------------------+ 1 ********************************************************************** J U M P E R S ********************************************************************** BASF 6180 FIXED DISK DRIVE SPECIFICATION 80307-054, 11/82 Jumper Setting ============== User Selectable Options ----------------------- The BASF 6180 has 8 switches for the selection of different options: +------+ | O--O |1 Drive Select 1 | O--O |2 Drive Select 2 | O--O |3 Drive Select 3 | O--O |4 Drive Select 4 | O--O |5 DRSEL | O--O |6 PWRON | O--O |7 REZERO | O--O |8 PERMSELD +------+ Four switches (1 - 4) are used to set the drive address. Drive selection is performed when the DR SEL (Drive Select) signal corresponding to the switch setting is active. Two switches (5 and 6) are used to control the condition for the spindle motor start. Depending on the switch setting the Spindle Motor is started either with the first active going edge of the corresponding DR SEL (Drive Select) signal or when DC power is provided to the drive. Only one of two switches may be set. Switch 7 is used to enable an automatic Rezero operation after the Spindle Motor has reached full speed. Switch 8 allows to select a drive permanently and independent of the state of the DR SEL (Drive Select) signals. Drive Selection --------------- Each drive is assigned an address by setting the corresponding Drive Select switch in the drive. Drive selection is done by activating the corresponding DR SEL (Drive Select) signal through the control unit. The selected drive responds the to all input signals and enables its output drivers. Alternatively the drive may be permanently selected through an option switch if only one drive is connected to the controller. Rezero ------ After Power On the drive's positioning system must be recalibrated by performing a seek to Track Zero. This can be done either automatically by the drive or by the controller through the interface in the following way: - select drive - deactivate DIR IN (Direction In) - provide STEP pulses until TRK 0 (Track 0) becomes active ********************************************************************** I N S T A L L ********************************************************************** BASF 6180 FIXED DISK DRIVE SPECIFICATION 80307-054, 11/82 Notes on Installation ===================== Drive mounting -------------- x horizontally x vertically +-x-------------x-+ +--+ +--+ +------------------+ | x x | | +-----+ +-----+ | | | x | x x | | | | | | | x+----------------+x +-+---------x-------+-+ | | | | | | ||x x|| +--------x-----x------+ | | | | | | || x x || x x | | | | | | || x x || | | | | | | || x x || +---------------------+ | +-----+ +-----+ | || xx || +-+-----------------+-+ +--+ +--+ || x x || | | || x x || | | || x x || +-----------------+ |x x| x++----------------++x UNACCEPTABLE! The BASF 6180 may be operated only when the Face Place is in a vertical plane. The maximum deviation is an angle of 13 degrees. From the remaining four possible orientations only three are allowed for operation. These are with the Read-Write-Control PCB either on the left or right side or on top of the drive. Operation with the Read- Write-Control PCB at the bottom of the drive is not allowed. Housing ------- The sealed module consists of an aluminium molded chassis and cover. A closed loop air filtering system inside constantly cleans the air particles which may be generated by head to disk interference. An absolute breather filter for pressure equalization with the ambient air pressure protects against environmental contamination. Physical Interface ------------------ The physical interface between the BASF 6180 and the controller is done via three or four connectors. One provides the control and status lines through the "A"-cable which may be daisy chained. The second one provides the read/write signals to the star connected "B"-cable. The other connectors are used to supply DC power and for optional frame grounding. Interface Connector J1, "A"-cable --------------------------------- The "A"-cable is connected to the PC-board via a 34 pin card edge connector. Recommended mating connector is AMP P/N 88 373-3, or equivalent. The "A"-cable may be daisy-chained if more than one drive is connected to the controller. The cable may be flat ribbon or twisted pair with a maximum total length of 6m (20 ft). Interface Connector J2, "B"-cable --------------------------------- The "B"-cable is connected to the PC-board via a 20 pin card edge connector. Recommended mating connector is AMP P/N 88 373-6, or equivalent. The "B"-cable must be radially connected if more than one drive is connected to the controller. The cable may be flat ribbon or twisted pair with a maximum total length of 6m (20 ft). The cable impedance should be around 105 Ohms. Power Connector J3 ------------------ The DC-power connector is a four pin connector. Recommended mating connector is AMP P/N 1-480424-0 with pins 350078-4, or equivalent. Pin 1 +12 VDC Pin 2 GND 12V Pin 3 GND 5V Pin 4 + 5 VDC Frame Ground Connector J4 ------------------------- The frame of the BASF 6180 may be connected to the system ground through a separate cable connected to J4. Normally the frame of the BASF 6180 is connected to logic ground. If JJ4 is used, then the solder jumper wire JJ2 at location 1G of the Read-Write-Control PCB should be removed in order to avoid ground loops. Recommended mating connector for J4 is AMP P/N 62187-1 or equivalent. ********************************************************************** F E A T U R E S ********************************************************************** BASF 6180 FIXED DISK DRIVE SPECIFICATION 80307-054, 11/82 General Description ------------------- The BASF 6180 is a family of 5.25" Fixed Disk Drives. The three models of the family offer capacities of 6.38 MBytes (BASF 6182), 9.57 MBytes (BASF 6183), and 14.35 MBytes (BASF 6184). The BASF 6180 stores the information on up to 3 non-removable disks and up to 230 cylinders. The BASF 6180 uses the industry standard interface and dimensions to ease system integration. Up to four BASF 6180 may be connected to one controller. For systems requiring removable media it is re- commended to use the BASF 6180 in combination with BASF Mini Floppy Disk Drives, which offer a capacity of up to 1 MByte. Seek Time --------- +----------------------------------+--------+ | | 6180 | +----------------------------------+--------+ |Track-to-Track msec. typ. | 1.2 | +----------------------------------+--------+ |Average msec. typ. | 61 | | msec. max. | 182 | +----------------------------------+--------+ |Latency msec. avg. | 8.3 | +----------------------------------+--------+ Disk Media Defects ------------------ Disk drives are allowed to have the following number of media defects when leaving the factory: BASF 6182 7 max. BASF 6183 10 max. BASF 6184 15 max. Cylinder zero is delivered error free.